NoComplaintReasonRemedy
1Machine does not work , power indicating LED doesnotglow1.No power supply 2.MCB tripped1.Restore power supply 2.Check the wiringfor anyshort circuit. Ifsatisfactory reset the MCB
2Conveyor is not moving1.Conveyor speed set to 0 2.Conveyor motor stalling 3.Defective conveyor motor 4.Conveyor chaindisengaged fromthe sprockets. 5.Conveyor chainbreakage 6.Defective conveyor drive sprocket 7. Defective ACvariable speed drive1.Increase the conveyor speed 2.Reduce load onthe conveyor. Install themachine witha slope towards the direction ofthe conveyor movements to increase the load carrying capacity ofthe conveyor. 3.Rectify/replace the conveyor motor 4.Engage the conveyor chain with the sprocket. 5.Replace bothchain together to avoid themismatching ofchains 6.Replace the conveyor drive sprockets 7. Replace ACvariable speed drive
4Air blower not working1.Defective blower motor1.Replace the blower motor
5.Blower motor works , but the blower does not rotate freely1.Blower tightening nut loose.1.Tighten blower to blower motor.
6.Insufficient shrinking1.Low temperature setting. 2.Temperature is not building up1.Increase the temperature setting. 2.Refer tocomplaint no.7
7.Temperature is not buildingup.1.Heater connection loose. 2.Heater failure. 3.Low temperature setting 4.Defective contactor for heaters1.Make proper connections. 2.Replace the defective heater 3.Increase temperature setting 4.Replace the defective contactor
8Excessive Shrinking1.Hightemperature setting. 2.Low conveyor speed. 3.Defective Temperature sensor 4.Defective contactor for heaters dueto contact welding1.Reduce the temperature setting. 2.Increase the conveyor speed. 3.Replace the defective part. 4.Replace the defective contactor
9.Shrinking not uniform1.Blower not working or loose. 2.Heaters are not working.1.Refer complaint troubleshooting Case4and 5. 2.Identify the defective heaters and replace them.
10.Abnormalsound andvibration1.Blower loose. 2.Blower motor bearing failure. 3.Machine is notinstalled ona level surface.1.Tighten the nut with which theAir Turbulence Fanis attached to the blower motor 2.Replace the defective bearing. 3. Correct the level the machine.
11.Conveyor is moving constant speedat1.Defective speed controller1.Replace speed controller
12Display Black out whenHeater are turnedon.1.EMI generated through contactor arcing.1.Replace contactor connections for loose terminals. 2.Connect a 220ohm resistor anda 104/1kv capacitor in series across A1and A2ofcontactor. 3.Replace Contactor.