No.ComplaintReasonsRemedy
1.Machine doesnot work1.No power supply. 2.MCB tripped. 3.No output fromCT18V.1.Restore power supply. 2.Check the wiringfor anyshortcircuit. If satisfactory, reset the MCB. 3.Check andreplace if defective.
2.Air blower is not working1.Defective blower motor. 2.Defective capacitor. 3.Nosupply at motor end.1.Replace the blower motor. 2.Replace the capacitor. 3.Check andrestore the supply.
3.Blower motor works , but the blower doesnot rotate freely1.Shaft fitting Allen screw loose.(a)Check the fanshaft assembly. (b)Ensure free rotation of theshaft anda little axial play. (c)Refit the FanAssembly Mounting Plate.
4.Conveyor is movingat constant speed1.Defective speed controller.1.Replace the speed controller.
5.Conveyor is not moving1.Conveyor speed set to zero. 2.Conveyor motorstalling. 3.Defective conveyor motor. 4.Conveyor chain disengaged fromthe sprockets. 5.Conveyor chain breakage. 6.Defective conveyor drive sprocket. 7.Defective ACvariable speed drive.1.Increase the conveyor speed. 2.Reduce loadonthe conveyor. Install themachine witha slope towards the direction of the conveyor movements to increase the load carrying capacity ofthe conveyor. 3.Rectify/replace the conveyor motor. 4.Engage the conveyor chain withthe sprocket. 5.Replace both chaintogether to avoid themismatching ofchains. 6.Replace the conveyor drive sprockets. 7.Replace ACvariable speed drive.
6.Conveyor chainslips fromthe guides1.Lower conveyor tension. 2.Misalignment of sprockets.1.Increase the tension byadjusting the conveyor tension adjusting bolt. 2.Align the sprockets andchain rails.
7.Insufficient shrinking1.Low temperature setting. 2.Temperature is not building up1.Increase the temperature setting. 2.Refer to complaint no.7
8.Temperature is not building up.1.Electric heater connection loose. 2.Electric heater failure. 3.Low temperature setting. 4.Defective contactor for electric heaters.1.Make proper connections. 2.Replace the defective electric heater. 3.Increase temperature setting. 4.Replace the defective contactor
9Excessive Shrinking1.High temperature setting. 2.Low conveyor speed. 3.Defective Temperature sensor. 4.Defective contactor for electric heaters dueto contact welding.1.Reduce the temperature setting. 2.Increase the conveyor speed. 3.Replace the defective part. 4.Replace the defective contactor.
10Shrinking is not uniform1.Blower is not working or loose. 2.All the electric heaters are not working.1.Refer complaint 4and5. 2.Identify the defective electric heaters andreplace.
11.Abnormal sound andvibration1.Blower loose. 2.Motor bearing failure. 3.Machine is not installed on a level surface.1.Tighten the nutwith which the Air Turbulence Fanis attached to the blower motor 2.Replace the defective bearing. 3.Correct the levelthe machine.
12Display black outwhe Heater are turned on.n1.EMI generated through contactor arcing.1.Replace contactor connections for loose terminals. 2.Connect a 220ohm resistor anda 104/1kv capacitor in series across A1and A2ofcontactor. 3.Replace Contactor.
13Display black outwhile pressing control buttons.1.Low supply voltage.1.Ensure the proper operating voltage