NoProblemReasonRemedy
1.Machine doesnot seal and power is not availableNo ACSupply.Check the power supply andMains Cord.
2.Machine doesnot Seal when the Rocker Armis pressed down,Power is available, SealingLED does not glowMicro Switch doesnot operate. Control Supply is not available.Adjustthe Micro Switch Plunger. Check the Micro Switch,if defective, replace it. Check the output ofthe Control Transformer andif founddefective replace it. Ifcontrol supply of15-18V is available, Sealing Timer PCBmaybe defective, replace itwith a newone.
3.Machine doesnot seal, SealingLED glows whenthe Rocker Armis pressed down andis out after set time then the Buzzer starts beepDefective Auxiliary Relay. BurntHeating Element.Replace the Auxiliary Relay. Replace with newHeating Element.
4.Machine doesnot seal and SealingLED blinksDefective Sealing Timer.Replace the Sealing Timer PCB.
5.Machine doesnot seal and sealing LED flickersDefective Sealing Timer.Replace the Sealing Timer PCB.
6.Machine seals continuously whenthe rocker armis pressed down. Sealing LED glowsandis put outafter the set time then the Buzzer starts beepDefective Sealing Timer. Defective Auxiliary relay.Defective Sealing Timer PCB. Replace the auxiliary relay.
7.Heating Element fails very fastHigher Sealing Time.Reduce the time setting by adjusting the Sealing Time Control Knob.
8.Machine doesnot seal but timer works andAuxiliary relay is energized.Defective Main Transformer.Replace the Main Transformer.