| 1 | Machine doesn’t work/No display | 1.No AC supply. 2.MCB tripped. 3.Mains cord failure. 4.No control transformer output. 5.Power Switch/FRC cable damage | 1.Restore AC supply. 2.Check for any short circuit or reset the MCB. 3.Replace mains cord. 4.Check the voltages & replace it if defective. 5. Replace the Display pcb/FRC cable |
| 2 | Conveyor is not working | 1.Conveyor belt tension may be too high/low. 2.Defective capacitor of motor. 3.Relay board damage 4.Defective motor. 5. | 1.Adjust the tension. 2.Replace the capacitor. 3. Replace the defective 1.4. Check the motor connection for any breakage and replace it if defective. |
| 3 | Film feeding is not doing/Film roller is not moving | 1.Defective limit switch. 2.Defective motor/Capacitor. 3.Defective motor. 4.Defective relay PCBA. 5.The tension shaft is not on the level. 6.The position of tension roller is not proper. 7.The triangular plate is not properly fixed 8.The tension of clamping chain is too tight or loose. | 1.Check the connections and replace it if defective. 2.Replace the defective part. 3.Replace it. 4.Check and replace the defective. 5.Adjust it. 6.Adjust it. 7.Adjust it. 8.Adjust or lubricate it. |
| 5 | Machine doesn’t seal/Improper sealing | 1.Low air pressure. 2.Defective cartridge heater. 3.Defective relay PCBA. 4.Defective temperature controller/ temperature sensor. 5.Voltage is too low. 6.Incorrect parameters settings. 7.Defective sealing blade. 8.Defective teflon tape. 9.Defective limit switch. | 1.Check and correct it. 2.Check for any open circuit and replace it if defective. 3.Check and replace the defective. 4.Replace the defective part. 5.Check the voltage. 6.Adjust the parameters as per film and product. 7.Replace it. 8.Replace them. 9.Replace it. |
| 6 | Error messages doesn’t work properly | 1.Open connections. 2.Defective limit switch. 3.Misaligned sensor/ Defective sensor. | 1.Check and do proper connections. 2.Check and replace if defective. 3.Adjust the position/Replace it if defective. |
| 7. | Waste film collection system is not working properly. | 1.Poor quality film. 2.Defective motor/Capacitor. 3.Incorrect alignment of guiding rollers. | 1. Use quality film. 2. Replace the capacitor/motor. 3.Adjust the guiding rollers adjacent to the outer conveyor. |