| Filmrelease motordoesnot work | Pressedemergencyswitch | Resetemergencyswitch |
| Chainslipped | Restorechain |
| Relaydamaged | Replacerelay |
| Microswitchisn’tatrightposition | Adjustmicroswitchposition |
| Defectivemicroswitch | Replacemicroswitch |
| Pushing air-cylinder doesn’twork | Compressedairsupplynotavailable | Restore compressedairsupply |
| Pushingmicroswitchdefective | Replacemicroswitch |
| Pushsolenoidvalvedefective | Replacesolenoidvalve |
| Sealing air-cylinder doesn’twork | Sealbarlevelsensorsnotatcorrectposition | Setsealbarsensorstocorrect position |
| Sealingsolenoidvalvedefective | Replacesolenoidvalve |
| Thefilmdoes notsealandcut off | Sealingtemperaturesetlow | Increasethesettemperature |
| Defectivetemperaturecontroller | Replacetemperaturecontroller |
| Defectivecartridgeheater | Replacecartridgeheater |
| Cuttingbladedamaged | Replacecuttingblade |
| Thesealingbladesandcuttingbladearenot atproperlevels | Sealingbladesshouldbe0.4-0.5 mmabovethebottomlevelof cuttingblade.Adjustproperly |
| Badsealing | Surfaceofsealer orcutterdamaged | Replacesealerorcutter |
| Depositofplasticorotherforeignbodyon theblades | Cleanwithdrycottoncloth |