7. Installation

  • Filling vacuum pump with oil

13. Starting the machine

  • Starting the machine

7. INSTALLATION

  • Open the back cover & fill vacuum oil.
  • Give three phase power & check the phase sequence indicator.
  • Switch on the MCB & then press the power button on the front panel.
  • Set parameters (vacuum level, flushing level, sealing time & cooling time) as per product & pouch.
  • Shutdown process: switch off the MCB.

8. FILLING VACUUM PUMP WITH OIL

  • There is no vacuum pump oil in the newly delivered machine. If the vacuum pump works without oil it will damage the pump, even in a short time. Please make sure that the vacuum pump has been filled with the oil up to the mark before the start-up.
  • Open the side cover.
  • Fill the vacuum pump with Sevol V/equivalent vacuum pump oil.
  • Check the oil level is between 1/2 and 3/4 of the oil level indicator. If it is less than 1/2, please add more.
  • If the oil level is between 1/2 and 3/4 of the oil level indicator then close the cap and fix the side door.

11. CONTROL PANEL

  • LCD display
  • Control buttons
  • Phase indicator
  • MCB 3 pole
  • 500VSLG User manual

12. PROGRAM MODES

  • Sevana’s micro-processor based vacuum machine has 4 preset modes or programs. Each program can be set with different parameters. Variable parameters in each mode are
  • Vacuum level
  • 0-760mm Hg( Vacuum level in the chamber)
  • Flush(Gas2)
  • Vacuum levels represents in millimeter mercury up to vacuum has to be achieved (-760mmHg absolute vacuum, 0 is normal atmospheric pressure).
  • Flush 1 represents level up to which gas is flushed. If vacuum level is 760and flush 1 is 500, chamber is vacuumized to level 760mmHg and the gas is flushed to the chamber till vacuum level reaches 500.Always set
  • Flush 2 & Flush 3 on 760.
  • TO FLUSH THE GAS:

13. STARTING THE MACHINE

  • Stop/Reset
  • Set
  • A LCD check function is done first. Version of the software is displayed.
  • VACUUM LEVEL
  • Now the lid is closed, then vacuum increases up to the preset level.
  • When the vacuum is built up to the preset level the message will change to an indication given below.
  • After that the lid open automatically and the display changes to “ready mode”
  • Press the “STOP” button for 1 second.

14. OPERATION

  • Switch on the supply
  • Adjust the vacuum and other parameters
  • Select the required mode
  • Insert the product into the film pouch and then place it in the vacuum chamber in such a way that the open end of the pouch is in between sealing element and jaw.
  • Close the lid.