10. Setting up the machine for operation
- Setting up the machine for operation
11. Film roll mounting
12. Operation
- 13.
- Collection of waste film
- 14.
- Microcontroller settings
9. CONTROL PANEL
- Power On/Off switch (MCB)
- Bridge ON/OFF switch
10. SETTING UP THE MACHINE FOR OPERATION
- is 6Kg/ Sq.Cm. Also ensure that both power sources are of the required capacity of the machine.
- machine is better than 100 MΩ at 500 V DC. Remove the shorting and connect the electric power with sufficient current carrying capacity cable from a suitably rated switch fuse unit or MCB outlet. Connect the pneumatic supply.
- 3. Turn on the power switch. The POWER ON LED will be light up.
- 5. Set the sealing temperature to required value.
- 6. Select the preset mode. Set the sealing time and product advance values.
- 7. Adjust the height between the film guiding triangular plates (21 & 22) for the object to
- 8. Load the shrink film on the film support rollers and guide the film as per the route as
- 9. Adjust the guide on the conveyor as per the size of the object to be packed.
11. FILM ROLL MOUNTING
- Switch off the machine during the mounting of the film and setting it up to avoid any injuries.
- i. Put film roller on the two supporting rollers.
- turning plates, spreading on to that and making a 45 degree turn such that the inside of the film becomes out side and pull it further and clamp as shown in the diagram.
12. OPERATION
- 1. Switch on the machine.
- Set the temperatures of the sealing jaws depending on the type and thickness of film.
- 3. Set the sealing time and product advance time in preset/mode. The recommended
- 4. Set the distance between the sealing line and the end of packing.
- 5. Adjust the distance between the triangular plates to match with the height of object to
- 6. After the set temperature has reached, pack a few packets by the manual mode.
- Shrink the samples. If required, alter the settings for the best results.
- 7. After the final adjustments and trials, put the machine on auto mode and start
14. MICROCONTROLLER SETTINGS
- Preset mode/program can be selected by pressing the MODE/RESET switch.
- In the automatic modes we can set two parameters.
- If the air pressure is too low to seal:
- If the emergency stop button is pressed:
- Correct the error and press the MODE/RESET button to continue.
- CHECK & RESET
- EMERGENCY STOP