← Back
User Manuals
User Manual for QS5545LABV2.1
Updated 11 Oct 2026
Applies to: QS5545LABV21
10. Setting up the machine for operation
- Setting up the machine for operation
11. Film roll mounting
12. Operation
- 13.
- Collection of waste film
- 14.
- Microcontroller settings
9. CONTROL PANEL
- Power on/off switch (MCB)
- Bridge on/off switch
- Fix board I of blade slot
- Fix board II of blade slot
- String press board
10. SETTING UP THE MACHINE FOR OPERATION
- Sealing jaw is pneumatically operated. Use 8mm PU tube to connect compressed air supply of
- 6Kg/cm2 to FRL(Filter Regulator Lubricator) provided with the machine & regulate the air pressure.
- Release the Emergency stop button.
- Turn on the MCB. The power on LED will be light up.
- Set the sealing time and shall be in the range of 150oC – 180oC.
- Load shrink film on film support rollers and guide the film as per diagram shown.
- Adjust the height between film guiding triangular plates and guide on the conveyor as per the product.
- Select manual mode, then press down/feed button to feed the film and lead the film to waste film spool as per diagram shown.
11. FILM ROLL MOUNTING
- Switch off the machine during the mounting of the film and setting it up to avoid any injuries.
- Put film roller on the two supporting rollers. ii.
- Pull additional 30cm of film and pass it through the upper and lower triangular film turning plates, spreading on to that and making a 45 degree turn such that the inside of the film becomes out side and pull it further and clamp as shown in the diagram.
12. OPERATION
- Switch on the machine.
- Set the temperatures of the sealing jaws depending on the type and thickness of film. The range of temperature shall be 150°C-180°C.
- Set the sealing time and product advance time in preset/mode. The recommended “’Product
- Set the distance between the sealing line and the end of packing.
- Adjust the distance between the triangular plates to match with the height of object to be packed. It is recommended to add 10 mm more for shrinkage of film.
- After the set temperature has reached, pack a few packets by the manual mode. Shrink the samples.
- After the final adjustments and trials, put the machine on auto mode and start continuous operation.
- Bridging mechanism can be enabled or disabled by Bridge ON/OFF switch on the control panel. Software option is also provided. This mechanism is especially suitable for packing small products. If the mechanism is enabled, the gap between in feed conveyor belt & out feed one sho...
14. MICROCONTROLLER SETTINGS
- Preset mode/program can be selected by pressing the MODE/RESET switch.
- In the automatic modes we can set two parameters.
- If the air pressure is too low to seal:
- If the emergency stop button is pressed:
- Correct the error and press the MODE/RESET button to continue.
- Software option is provided to enable or disable bridging mechanism. Press up or down button to change the value.
- CHECK & RESET
- EMERGENCY STOP