10. Setting up the machine for operation

  • Setting up the machine for operation

11. Film roll mounting

  • Film roll mounting

12. Operation

  • 13.
  • Collection of waste film
  • 14.
  • Microcontroller settings

9. CONTROL PANEL

  • Power on/off switch (MCB)
  • Fix board I of blade slot
  • Fix board II of blade slot
  • String press board

10. SETTING UP THE MACHINE FOR OPERATION

  • 2. Sealing jaw is pneumatically operated. Use 8mm PU tube to connect compressed air supply of 6Kg/cm2 to
  • FRL(Filter Regulator Lubricator) provided with the machine & regulate the air pressure.
  • 3. Release the Emergency stop button.
  • 4. Turn on the MCB. The power on LED will be light up.
  • 6. Set the sealing time and temperature.
  • 8. Load shrink film on film support rollers and guide the film as per diagram shown.
  • 9. Adjust the height between film guiding triangular plates and guide on the conveyor as per the product.
  • 10. Select manual mode, then press down/feed button to feed the film and lead the film to waste film spool as

11. FILM ROLL MOUNTING

  • Switch off the machine during the mounting of the film and setting it up to avoid any injuries. i.Put film roller on the two supporting rollers. ii.Release the film perforator by turning 90 degrees. iii.Pull the film and pass it as per the drawing given below till it passes th...

12. OPERATION

  • 1. Switch on the machine.
  • 2. Set the temperatures of the sealing jaws depending on the type and thickness of film.
  • 3. Set the sealing time and product advance time in preset/mode. The recommended “’Product Advance”
  • 4. Set the distance between the sealing line and the end of packing.
  • 5. Adjust the distance between the triangular plates to match with the height of object to be packed. It is
  • 6. After the set temperature has reached, pack a few packets by the manual mode. Shrink the samples. If
  • 7. After the final adjustments and trials, put the machine on auto mode and start continuous operation.

14. MICROCONTROLLER SETTINGS

  • Preset mode/program can be selected by pressing the MODE/RESET switch.
  • In the automatic modes we can set two parameters.
  • If the air pressure is too low to seal:
  • If the emergency stop button is pressed:
  • Correct the error and press the MODE/RESET button to continue.
  • CHECK & RESET
  • EMERGENCY STOP