← Back
User Manuals
User Manual for QS5545LAV2
Updated 11 Oct 2026
Applies to: QS5545LAV2
10. Setting up the machine for operation
- Setting up the machine for operation
11. Film roll mounting
12. Operation
- 13.
- Collection of waste film
- 14.
- Microcontroller settings
9. CONTROL PANEL
- Power on/off switch (MCB)
- Fix board I of blade slot
- Fix board II of blade slot
- String press board
10. SETTING UP THE MACHINE FOR OPERATION
- Sealing jaw is pneumatically operated. Use 8mm PU tube to connect compressed air supply of
- 6Kg/cm2 to FRL(Filter Regulator Lubricator) provided with the machine & regulate the air pressure.
- Release the Emergency stop button.
- Turn on the MCB. The power on LED will be light up.
- Set the sealing time and shall be in the range of 150oC – 180oC.
- Load shrink film on film support rollers and guide the film as per diagram shown.
- Adjust the height between film guiding triangular plates and guide on the conveyor as per the product.
- Select manual mode, then press down/feed button to feed the film and lead the film to waste film spool as per diagram shown.
11. FILM ROLL MOUNTING
- Switch off the machine during the mounting of the film and setting it up to avoid any injuries.
- Put film roller on the two supporting rollers. ii.
- Pull additional 30cm of film and pass it through the upper and lower triangular film turning plates, spreading on to that and making a 45 degree turn such that the inside of the film becomes out side and pull it further and clamp as shown in the diagram.
12. OPERATION
- Switch on the machine.
- Set the temperatures of the sealing jaws depending on the type and thickness of film. The range of temperature shall be 150°C-180°C.
- Set the sealing time and product advance time in preset/mode. The recommended “’Product
- Set the distance between the sealing line and the end of packing.
- Adjust the distance between the triangular plates to match with the height of object to be packed. It is recommended to add 10 mm more for shrinkage of film.
- After the set temperature has reached, pack a few packets by the manual mode. Shrink the samples.
- After the final adjustments and trials, put the machine on auto mode and start continuous operation.
14. MICROCONTROLLER SETTINGS
- Preset mode/program can be selected by pressing the MODE/RESET switch.
- In the automatic modes we can set two parameters.
- If the air pressure is too low to seal:
- If the emergency stop button is pressed:
- Correct the error and press the MODE/RESET button to continue.
- CHECK & RESET
- EMERGENCY STOP
Documents