7. INSTALLATION

  • Open the side door & fill the vacuum oil.
  • Give three-phase power & check the phase sequence indicator.
  • Connect the gas cylinder to the machine with the PU tube.
  • Switch on the MCB & then press the power button on the front panel.
  • Set parameters (vacuum level, flushing level, sealing time & cooling time) as per product & pouch.
  • Shutdown process: switch off the MCB.

8. FILLING VACUUM PUMP WITH OIL

  • There is no vacuum pump oil in the newly delivered machine. If the vacuum pump works without oil it will damage the pump, even in a short time. Please make sure that the vacuum pump has been filled with the oil up to the mark before the start-up.
  • Open the side cover.
  • Fill the vacuum pump with Sevol V/equivalent vacuum pump oil.
  • Check the oil level is between 1/2 and 3/4 of the oil level indicator. If it is less than 1/2, please add more.
  • If the oil level is between 1/2 and 3/4 of the oil level indicator then close the cap and fix the side door.

12. CONTROL PANEL

  • LCD display
  • Control buttons
  • Phase indicator
  • MCB 3 pole
  • 600VSG Twin User manual

13. PROGRAM MODES

  • Sevana’s micro-processor-based vacuum machine has 3 preset modes or programs. Each program can be set with different parameters. Variable parameters in each mode are
  • Vacuum Mode
  • Flush Mode
  • Vacuum level
  • Flush
  • Vacuum error
  • Flush represents level up to which gas is flushed. If the vacuum level is 100% and the flush is 60%, the chamber is vacuumed to 100% and the gas is flushed into the chamber till the vacuum level reaches 60%. For calculating the flushing percentage, take the difference between...
  • To change the modes, first press the Mode button. The display will show like below,

14. STARTING THE MACHINE

  • Stop/Reset
  • Set
  • A LCD check function is done first. A version of the software and the count is displayed.
  • The set parameters can be modified by the operator if required. The machine will automatically go to the previously used mode after initializing.
  • Now the lid is closed, the vacuum increases up to the preset level.
  • When the vacuum is built up to the preset level the message will change to an indication given below.
  • In Timer Mode, all parameters are configured in seconds. The pump activates based on the designated vacuum duration, while the flush initiates according to the set flush time. Balance working is the same as vacuum/flush mode.
  • Press the “STOP” button for 1 second.

15. OPERATION

  • Switch on the supply
  • Adjust the vacuum and other parameters
  • Select the required mode
  • Insert the product into the film pouch and then place it in the vacuum chamber in such a way that the open
  • end of the pouch is in between sealing element and jaw. If using flushing, insert the nozzle inside the pouch.
  • Close the lid.