User Manual for QS600VSTWINBV2
Updated 11 Oct 2026
Applies to: QS600VSTWINBV2
6. Installation
- Filling vacuum pump with oil
11. Starting the machine
6. INSTALLATION
- Open the back door & fill vacuum oil.
- Give three phase power & check phase sequence indicator.
- Switch on the MCB & then press power button on the front panel.
- Set parameters (vacuum level, flushing level, sealing time & cooling time) as per product & pouch.
- Shutdown process: switch off the MCB.
7. FILLING VACUUM PUMP WITH OIL
- There is no vacuum pump oil in the newly delivered machine. If the vacuum pump works without oil it will damage the pump, even in a short time. Please make sure that the vacuum pump has been filled with the oil up to the mark before the start-up.
- Open the back cover.
- Fill the vacuum pump with Sevol V/equivalent vacuum pump oil.
- Check the oil level is between 1/2 and 3/4 of the oil level indicator. If it is less than 1/2, please add more.
- If the oil level is between 1/2 and 3/4 of the oil level indicator then close the cap and fix the back door.
- Seal to seal distance(mm)
9. CONTROL PANEL
- LCD display
- Control buttons
- Power LED
- Phase indicator
- MCB 3 pole
- 600VS Twin User manual
10. PROGRAM MODES
- Sevana’s micro-processor based vacuum machine has 4 preset modes or programs. Each program can be set with different parameters. Variable parameters in each mode are
- Vacuum level
- 0-760mm Hg( Vacuum level in the chamber)
- Vacuum levels represents in millimeter mercury up to vacuum has to be achieved (760mmHg absolute vacuum, 0 is normal atmospheric pressure).
- Select the mode by pressing “MODE” button
- To set the parameters press “SET” button.
- To change the vacuum press the “UP” or “DOWN” button continuously till the required value is displayed.
- To select the next parameter and save the preset value press SET again.
11. STARTING THE MACHINE
- Connect the machine to appropriate power supply. Turn on the power switch to start the machine. The power switch locates at the right side of the machine. Turn the power switch to the position 1 to start- up.Then press the power button in the control panel.
- Stop/Reset
- Set
- VACUUM: 760mmHg
- VACUUM ERROR: OFF
- VACUUM: 0000mmHg
- A LCD check function is done first. Version of the software is displayed.
- VACUUM LEVEL
12. OPERATION
- Switch on the supply
- Adjust the vacuum and other parameters
- Select the required mode
- Insert the product into the film pouch and then place it in the vacuum chamber in such a way that the open end of the pouch is in between sealing element and jaw.
- Close the lid.
Documents
Pdf
User Manual for QS600VSTWINBV2