User Manual for QS780VSGV1
Updated 30 Sep 2026
Applies to: QS780VSGV1
7. Control panel
- Filling vacuum pump with oil
9. Power connection
11. Starting the machine
6. INSTALLATION
- Open the back door & fill vacuum oil.
- Give three phase power & check phase sequence indicator.
- Switch on the machine by press power button on the front panel.
- Set parameters (vacuum level, flushing level, sealing time & cooling time) as per product & pouch.
- Shutdown process: switch off the MCB.
- Vacuum pump oil
7. CONTROL PANEL
- 1.
- LCD display
- 2.
- Control buttons
- 3.
- Phase indicator
- 4.
- Power LED
8. FILLING VACUUM PUMP WITH OIL
- There is no vacuum pump oil in the newly delivered machine. If the vacuum pump works without oil it will damage the pump, even in a short time. Please make sure that the vacuum pump has been filled with the oil up to the mark before the start-up.
- 1. Open the back cover.
- 2. Fill the machine with Sevol V/equivalent vacuum pump oil (2000ml).
- 4. Close the oil filler plug.
- 6. Check the oil level is between 1/2 and 3/4 of the oil level indicator. If it is less than 1/2, please add more.
- 7. If the oil level is between 1/2 and 3/4 of the oil level indicator fix the back door.
9. POWER CONNECTION
- Check whether the supply voltage is as per the specification.
- Connect the power cord to three phase power socket.
- Isolate the power supply after use.
10. PROGRAM MODES
- Sevana microprocessor based vacuum machine has 4 preset modes or programs. Each program can be set with different parameters. Variable parameters in each mode are
- Vacuum level
- 0-760mm Hg( Vacuum level in the chamber)
- Flush(Gas2)
- Vacuum levels represents in millimeter mercury up to vacuum has to be achieved (-760mmHg absolute vacuum, 0 is normal atmospheric pressure).
- Flush 1 represents level up to which first gas is flushed. If vacuum level is 720and flush 1 is 500, chamber is vacuumized to level 720mmHg (95%vacuum) and first gas is flushed to the chamber till vacuum level reaches 500.
- Flush 2 represents level up to which second gas is flushed. If vacuum level is 720,flush 1 is 500 and flush 2 is
- 400(53% vacuum) chamber is vacuumized to level 720 and first gas is flushed to the chamber till vacuum level reaches 500,second gas is flushed to the chamber till vacuum level reaches 400.
11. STARTING THE MACHINE
- Stop/Reset
- Set
- A LCD check function is done first. Version of the software is displayed.
- VACUUM LEVEL
- Now the lid is closed, then vacuum increases up to the preset level.
- VACUUM ERROR: OFF
- When the vacuum is built up to the preset level the message will change to an indication given below.
- After that the lid open automatically and the display changes to “ready mode”
12. OPERATION
- Switch on the supply
- Adjust the vacuum and other parameters
- Select the required mode
- Select the sealing side by turning heater switch at front of machine.
- Insert the product into the film pouch and then place it in the vacuum chamber in such a way that the
- open end of the pouch is in between sealing element and jaw.
- Close the lid.